Properties
of phosphor R420-1 |
|
Chemical
formula |
CaWO4
|
Wavelength
of emission peak, nm |
420
|
Average particle
size, um |
4
- 7
|
Afterglow |
lower
than threshold sensitivity of nonsensitized X-ray films
|
Three types
of screens with phosphor R420-1 |
I
|
II
|
III
|
Intensifying
or photographic action (speed of survey), arb. units |
50
|
100
|
200
|
Modulation
transfer function at spatial frequency 2 line pair/mm |
0,60
|
0,35
|
0,30
|
Resolution
(sharpness, definition), arb. units |
100
|
80
|
70
|
General screen
characteristics |
High definition
and contrast of image |
Optimum ratio
between speed of survey and definition |
The highest
speed, short exposition time |
Object quality
on diagnostic photos: |
|
-excellent |
Skeleton
peripheral sections |
Jaw-facial
section of scull, thorax |
See screen
II, and also lumbar-sacrum section |
-good |
Jaw-facial
section of scull, thorax |
Skeleton
peripheral sections, alimentary canal, kinds of radiography |
Urinary
organs, thorax, blood-circulating system |